Dell PowerEdge C8000 User Manual

Page 42

Advertising
background image

40

Getting Started With Your System

Environmental

NOTE:

For additional information about environmental measurements for specific

system configurations, see the dell.com/environmental_datasheets.

Temperature

Operating

10 °C to 35 °C (50 °F to 95 °F) with a maximum
temperature gradation of 10 °C per hour

Storage

–40 °C to 65 °C (40 °F to 149 °F) with a
maximum temperature gradation of 20 °C per
hour

Relative Humidity

Operating

20% to 80% (noncondensing) with a maximum
humidity gradation of 10% per hour

Storage

5% to 95% (noncondensing)

Maximum vibration

Operating

0.26 Grms at 5–350 Hz

Storage

1.87 Grms at 10–500 Hz for 15 min

Maximum shock

Operating

One shock pulse in the positive z axis (one pulse
on each side of the system) of 31 G for 2.6 ms in
the operational orientation

Storage

Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse
on each side of the system) of 71 G for up to
2 ms;

Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse
on each side of the system) of 27 G faired square
wave pulse with velocity change at 235
inches/second (597 centimeters/second)

Advertising