I n f o r m a t i o n U p d a t e

www

.dell.com | support.dell.com

Processor 1 is a

533-MHz system bus

processor.

Processor 2 is a

533-MHz system bus

processor.

This system only

supports 400-MHz

system bus speed.

System halted!

Two 533-MHz processors are
installed. This system supports
only Intel Xeon 400-MHz front-
side-bus processors.

Reboot the system. If you
receive beep code 4-4-3
(processor frequency mismatch),
replace both processors with
Intel Xeon 400-MHz front-side-
bus processors. See "Processors"
in the Installation and
Troubleshooting Guide.

If a beep code does not occur at
system boot, turn off the system,
install the NVRAM_CLR
jumper, and reboot the system.
See Figure 5-2 in the Installation
and Troubleshooting Guide for
jumper locations.

Processor 1 is a

533-MHz system bus

processor.

This system only

supports 400-MHz

system bus speed.

System halted!

A 533-MHz processor is installed
in processor slot 1. This system
supports only Intel Xeon
400-MHz front-side-bus
processors.

Reboot the system. If you
receive beep code 4-4-3
(processor frequency mismatch),
replace processor 1 with an Intel
Xeon 400-MHz front-side-bus
processors. See "Processors" in
the Installation and
Troubleshooting Guide.

If a beep code does not occur at
system boot, turn off the system,
install the NVRAM_CLR
jumper, and reboot the system.
See Figure 5-2 in the Installation
and Troubleshooting Guide for
jumper location.

Ta b l e 1 - 1 .

S y s t e m M e s s a g e s ( c o n t i n u e d )

Message

Causes

Corrective Actions