Figure 1-2. removing the rack doors, Mounting the bridge onto the manifold, Place the manifold on a clean, flat surface – Dell PowerVault 35F (Fibre Channel Bridge) User Manual
Page 9: 0rxqwlqjwkh%ulgjh2qwrwkh0dqlirog

Dell PowerVault 35F Fibre Channel Bridge Rack Installation Guide
1-5
)LJXUH5HPRYLQJWKH5DFN'RRUV
3.
Perform steps 1 and 2 to remove the back door from the rack.
Store the two doors where they will not injure someone if they accidentally fall over.
0RXQWLQJWKH%ULGJH2QWRWKH0DQLIROG
The manifold comes with attached inner-slide rails. The bridge is attached to these
inner-slide rails using the four 6-32 x 1/4-inch panhead screws.
To mount the bridge, perform the following steps:
1.
Place the manifold on a clean, flat surface.
The word “top” is stamped on the manifold. Ensure that “top” is facing up.
2.
Place the bridge behind the manifold and between the two inner-slide rails.
Ensure that the bridge is upright and the end with the power and cable
connectors is facing away from the manifold.
hinge
release
lever