MAKING NETWORK CONNECTIONS

Length -

The maximum fiber optic cable length is 2 km (6558

feet), if system budgets are met. However, IEEE 802.3 FOIRL
(Fiber Optic Inter-Repeater Link) specifications specify a
maximum of 1 km (3279 feet).

3.3.2 Fiber Optic Interface (Fiber Optic Ports)

Ex040 and Ex040-X:

ST fiber optic ports

Parameter

Typical

Worst

Worst

Typical

Value

Case

Case

Budget

Receive

Budget

Sensitivity:

-30.5 dBm -28.0 dBm

Peak Input
Power:

-7.6 dBm

-8.2 dBm

Transmitter Power:

50/125

µ

m fiber: -13.0 dBm -15.0 dBm

13.0 dB

17.5 dB

62.5/125

µ

m fiber: -10.0 dBm -12.0 dBm

16.0 dB

20.5 dB

100/140

µ

m fiber: -7.0 dBm

-9.0 dBm

19.0 dB

23.5 dB

Error Rate:

Better than 10

-10

bit error rate.

NOTE:

The transmitter power levels and receive sensitivity levels given

above are Peak Power Levels after optical overshoot. A Peak Power Meter
must be used to correctly compare the values given above to those
measured on any port. If Power Levels are measured with an Average
Power Meter, add 3 dBm to the average power measurement to correctly
compare average power values to the peak power values.