Operating instructions, Vermont castings vcbvtn/tp & vcpvtn/tp room heater – Vermont Casting VCBV30TP - 30 User Manual

Page 8

Advertising
background image

8

Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater

Lighting Instructions

1. Read the safety information.

2. Make sure manual shut-off valve is fully open.

3. Push in gas control knob slightly and turn clockwise

to the OFF position.

4. WAIT 5 MINUTES TO CLEAR OUT ANY GAS. If

you then smell gas, STOP! Follow A in the safety
information. If you do not smell gas, go to next step.

5. Push in gas control knob slightly and turn counter-

clockwise

to ‘IGN PILOT.” The pilot can be

seen through the glass panel. If needed, keep
pressing and turning the control knob counterclock-
wise

until the pilot lights.

To Turn Off Gas To Heater

Turning Heater Off

Turn control knob clockwise to the OFF position.

Turning Burner Only Off (Pilot stays lit)

Turn control knob clockwise to the PILOT position.

CAUTION: Do not try to adjust heating levels by
using the manual shut-off valve.

NOTE: The thermostat has a sensing bulb and a
temperature control knob. The thermostat used on this
heater senses the room temperature and turns the
burner on and off. At times the room may exceed the
set temperature. If so, the burner will shut off. The
burner will cycle back on when room temperature drops
below the set temperature.

Operating Instructions

FOR YOUR SAFETY - READ THIS SECTION
BEFORE LIGHTING

WARNING: IF YOU DO NOT FOLLOW THESE
INSTRUCTIONS EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS OF LIFE.

A. BEFORE LIGHTING smell all around the appliance

area for gas. Be sure to smell next to floor because
some gas is heavier than air and will settle on the
floor.

IF YOU SMELL GAS:

1. Do not try to light any appliance.

2. Do not touch electrical switches; do not use any

phone in your building.

3. Immediately call your gas supplier from a

neighbor’s phone. Follow your gas supplier’s
instructions.

4. If you cannot reach your gas supplier, call the fire

department.

B. Use only your hand to push in or turn the gas valve

control knob. Never use tools. If the knob will not
push in or turn by hand, do not try to repair it, call a
qualified service technician. Force or attempted
repair may result in a fire or explosion.

C. Do not use this appliance if any part has been under

water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of
this control system and any gas control which has
been under water.

RH108

Fig. 8 Control knob.

1

2

3

4

5

6

7

PILOT

ON

OFF

IGN

NOTE: If pilot does not stay lit, refer to troubleshooting
section and contact a qualified service person, or gas
supplier for repairs. Until repairs are made, light pilot
with match.

6. Keep control knob pressed in for 30 seconds after

lighting pilot. After 30 seconds, release control knob.

7. If pilot goes out, repeat steps 3 through 6. This

heater has a safety interlock system. Wait one (1)
minute before relighting pilot.

8. When the pilot is lit, turn gas control knob to ON.

Turn thermostat control knob counterclockwise

to desired heating level. The main burner

should light. Set control knob to heat level between
7 and 1.

Advertising