Vertical (through the roof) vent assembly – Vermont Casting 4065 User Manual

Page 18

Advertising
background image

18

Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters

20007066

Vertical (Through the Roof)

Vent Assembly

NOTE: All vertically terminated installations must,
where specified, use the 2

¹⁄₄

” restrictor plate, to

comply with Vertical Termination Window (Fig. 8,
Page 8),
included in the hardware bag. The plate must
be installed within the firebox inner flue collar to insure
a proper air/fuel ration is maintained in an appliance
vented through the roof. (Fig. 32)

Make certain the vent system conforms to all other
requirements for vertical termination as specified on
Page 9.

This installation will require you to first determine the
roof pitch and use the appropriate vent components.
Refer to Page 10, Figure 9.

1. Locate the final position of the stove, observing all

clearances for both the vent and the stove.

2. Plumb to the center of the inner (4”) flue collar from

the ceiling above, and mark that location.

3. Cut the opening: (Page 17, Fig. 24)

9

³⁄₈

” x 9

³⁄₈

” (240 x 240mm)

4. Plumb any additional opening through the roof or

other construction that may be needed. In all cases,
the opening must provide a minimum of 1” (25mm)
clearance to the vent pipe.

5. Place the stove in its final position.

6. Install firestop(s) #7DVFS and Attic Insulation Shield

#7DVAIS as needed. (Fig. 33) If there is a room
above ceiling level, a firestop must be installed on
both the bottom and top sides of the ceiling joists. If
an attic is above ceiling level, an attic insulation
shield must be installed.

7. Install the appropriate roof support and flashing,

making certain that the upper flange of the flashing
base is below the shingles. (Fig. 34)

Waterproof Seal
Around Pipe

Firestop

Drain

4” Clearance

Snorkel
Termination
Cap

Wall Screws
and Anchors

ST218a

Gravel

Fig. 30 Snorkel kit installation.

Window Well

Recessed Wall

Sheet Metal
Screws and
Bracket

Wall Screws
and Anchors

Waterproof Seal
Around Pipe

ST219

Fig. 31 Use extension brackets to mount snorkel against
recessed wall.

Firestop

Finishing
Collar

7” Pipe

Wall Plate

6. Level the soil to maintain a 4” clearance below the

snorkel.

If the foundation is recessed, use extension brackets
(not supplied) to fasten the lower portion of the
snorkel. Fasten the brackets to the wall first, and
then fasten to the snorkel with self-tapping #8 x 1/2”
sheet metal screws. Extend the vent pipes out as far
as the protruding wall face. (Fig. 31)

Inner Flue Collar

2

¹⁄₄

” Restrictor Plate

Vent Starter Pipe

Seal all
around
crimped end

ST398c

Fig. 32 Install restrictor plate and starter pipe/inner elbow
assembly.