2 single-channel unit optical loss, Figure 6-1, Table 6-5 – Cisco ONS 15200 User Manual

Page 60

Advertising
background image

6-4

Cisco ONS 15200 Product Description

78-13766-01

Chapter 6 Engineering Specifications

Optical

Figure 6-1

15252 MCU optical path

6.2.3.2 Single-Channel Unit Optical Loss

Table 6-5

provides optical loss information for the SCU. See

Figure 6-2

and

Figure 6-3

to locate the

paths where loss occurs in the SCU (for example, from I to H in a Collector Filter Module [CFM]).

Figure 6-2

shows an unprotected path, and

Figure 6-3

shows a protected path in the SCU.

Insertion loss, MU-type

0.3

Insertion loss, SC-type

0.3

Table 6-4

MCU Optical Loss (continued)

Equipment

Maximum (dB)

Includes
connectors
(Y/N)

61890

LM A

NAM 1

Filterbank A

X

10% input/output

monitor A

H

P

O

V

V

HFM 1A

HFM 2A

CLIP 1

LM B

NAM 2

Filterbank B

Y

10% input/output
monitor B

I

M

N

B

K

R

HFM 2B

HFM 1B

CLIP 2

Table 6-5

SCU Optical Loss

Equipment

Maximum (dB)

Includes
connectors
(Y/N)

Collector Filter Module: Unprotected (100/0 or 0/100)

Through loss (adjacent channel), I to H

0.9

Y

Through loss (non-adjacent channel), I to H

0.8

Y

Drop loss, I to K

2.1

Y

100% Add loss, B to H

1.9

Y

Collector Filter Module: Protected (90/10 or 10/90)

Through loss (adjacent channel), I to H

1.4

Y

Advertising