Dell PowerEdge Rack Enclosure 4220 User Manual

Page 3

Advertising
background image

Cable Routing Procedures for Dell™ PowerEdge™ R810 Systems

Page 1

Contents

Introduction ........................................................................................................................................................... 2

Section 1: Cabling a Dell™ PowerEdge™ R810 With a Cable Management Arm (CMA) ......................... 2

1.1

Connecting the CMA Cables to the System ....................................................................................... 2

1.2

Routing the Power Cables Through the Strain Reliefs ...................................................................... 3

1.3

Routing the Cables Through the CMA ................................................................................................. 3

1.4

Left-Side Mounting Instructions ........................................................................................................... 3

1.5

Right-Side Mounting Instructions ......................................................................................................... 5

Section 2: Cabling a Dell™ PowerEdge™ R810 System Without a CMA .................................................... 6

2.1

Routing the Cables .................................................................................................................................. 6

2.2

Removing the CMA Brackets for Shallow Racks ................................................................................ 6

Section 3: Replacing a Power Supply on a PowerEdge™ R810 System With a CMA ................................ 7

3.1

Replacing a Power Supply with a Left-Side Mounted CMA .............................................................. 7

3.2

Replacing a Power Supply with a Right-Side Mounted CMA ........................................................... 7

Table of Figures

Figure 1: System with Cables Installed

.................................................................................................................. 2

Figure 2: Routing Power Cables Through the Strain Reliefs

............................................................................. 3

Figure 3: Routing the Cables Through the CMA

................................................................................................. 4

Figure 4: Left-Side Mounted CMA Installation

..................................................................................................... 4

Figure 5: Right-Side Mounted CMA Installation

.................................................................................................. 5

Figure 6: Cable Routing Without a CMA

............................................................................................................... 6

Figure 7: Removing the CMA Brackets for Shallow Racks

................................................................................. 6

Figure 8: Replacing the Power Supply

................................................................................................................... 7

Advertising