Dell PowerVault 220S (SCSI) User Manual

Page 2

Advertising
background image

file:///C|/Users/rishi_sood/Desktop/220s/New%20folder/en/readme/PV22xS_readme.txt[3/7/2013 12:21:08 PM]

* Center = split-bus mode
* Left = cluster mode

----------------------------------------------------------------------
Events that Require Rebooting
----------------------------------------------------------------------

Restart the host system whenever you change your system configuration
and the host system uses either of the following host bus adapters
(HBAs):
- Adaptec 3960D (39160)
- PERC 3/DI (on Dell PowerEdge(TM) 2500 and 4400 systems only)

Restart the storage system and the host system whenever you change the
bus configuration switch setting on the storage system.

----------------------------------------------------------------------
Microsoft(R) Windows(R) 2000 "New Hardware Found" Message
----------------------------------------------------------------------

If your system is running Windows 2000, the "New Hardware Found"
dialog box may appear prompting you to install a storage system
driver. To suppress the dialog box, install the "DellBP.inf" driver
file included in the Resource CD.

----------------------------------------------------------------------
Updating Your Firmware on Systems Running Dell OpenManage(tm)
----------------------------------------------------------------------

If your storage system is configured for split-bus mode and you
upgrade the Enclosure Management Module (EMM) firmware, the
correct version of the alternate EMM will not appear in the Array
Manager "Properties" window until after you cycle power to the 22xS
storage system.

======================================================================
SUPPORTED COMPONENTS
======================================================================

The PowerVault 22xS supports the following hardware and software
components. See the Dell website for updated support information.

----------------------------------------------------------------------
Supported Dell PowerEdge Systems
----------------------------------------------------------------------

* PowerEdge 600, 650, 700, 750, 1300, 1400, 1550, 1650, 1750, 1800,
1850, 2300, 2400, 2450, 2500, 2550, 2600, 2650, 2800, 2850, 3250,
4300, 4350, 4400, 4600, 6300, 6350, 6400, 6450, 6600, 6650, 7150,
7250, and 8450

----------------------------------------------------------------------
Supported Dell PowerVault Systems
----------------------------------------------------------------------

Advertising
This manual is related to the following products: