pdmLocaleLangu
age

pdmLocaleLangu
ageTag

.1.3.6.1.4.1.2699.2.4.1.15.1.1.2.1

String

R

DEFVAL { en-US }

pdmLocaleLangu
age

pdmLocaleLangu
ageTagEWS

.1.3.6.1.4.1.2699.2.4.1.15.2.0

String

R

DEFVAL { en-US }

pdmLocaleLangu
age

pdmLocaleLangu
ageTagOSD

.1.3.6.1.4.1.2699.2.4.1.15.3.0

String

R

DEFVAL { en-US }

pdmLocaleLangu
age

pdmLocaleLangu
ageTagWSM

.1.3.6.1.4.1.2699.2.4.1.15.4.0

String

R

DEFVAL { en-US }

pdmAudio

pdmAudioDescri
ption

.1.3.6.1.4.1.2699.2.4.1.16.1.0

String

R

DEFVAL { "" }

pdmAudio

pdmAudioVolum
e

.1.3.6.1.4.1.2699.2.4.1.16.2.0

Integer R/W

pdmAudio

pdmAudioMute .1.3.6.1.4.1.2699.2.4.1.16.3.0

Integer R/W

1. Muted
2. Not Muted

pdmAudio

pdmAudioTreble .1.3.6.1.4.1.2699.2.4.1.16.4.0

Integer R

DEFVAL { 0 }

pdmAudio

pdmAudioBass

.1.3.6.1.4.1.2699.2.4.1.16.5.0

Integer R

DEFVAL { 0 }

pdmAudio

pdmAudioBalanc
e

.1.3.6.1.4.1.2699.2.4.1.16.6.0

Integer R

DEFVAL { 0 }

pdmAlert

pdmAlertIndex

1.3.6.1.4.1.2699.2.4.1.18.1.1.1.1

Integer not-accessible

1

pdmAlert

pdmAlertGroupT
ype

1.3.6.1.4.1.2699.2.4.1.18.1.1.2.1

String

R

See Note 1

pdmAlert

pdmAlertGroupI
d

1.3.6.1.4.1.2699.2.4.1.18.1.1.3.1

String

R

See Note 1

pdmAlert

pdmAlertCode

1.3.6.1.4.1.2699.2.4.1.18.1.1.4.1

String

R

DEFVAL { "" }

pdmAlert

pdmAlertDescrip
tion

1.3.6.1.4.1.2699.2.4.1.18.1.1.5.1

String

R

Alert's condition has lamp
Fail, Lamp hours running out,
Projector Overheating, Lamp
Overheating and Fan Error.

pdmAlert

pdmAlertSeverity
Level

1.3.6.1.4.1.2699.2.4.1.18.1.1.6.1

Integer R

See Note 1

pdmAlert

pdmAlertTraining
Level

1.3.6.1.4.1.2699.2.4.1.18.1.1.7.1

Integer R

DEFVAL { 2 }

pdmAlert

pdmAlertDateTi
me

1.3.6.1.4.1.2699.2.4.1.18.1.1.8.1

String

R

DEFVAL
{ "1980-01-01T00:00:00" }

pdmAlert

pdmAlertPower
OnCount

1.3.6.1.4.1.2699.2.4.1.18.1.1.9.1

String

R

DEFVAL { "" }

pdmAlert

pdmAlertSysUpti
me

1.3.6.1.4.1.2699.2.4.1.18.1.1.10.1

String

R

DEFVAL { "" }

pdmAlert

pdmAlertCritical
AlertsCount

1.3.6.1.4.1.2699.2.4.1.18.2.0

Integer R

pdmAlert

pdmAlertAllAlerts
Count

1.3.6.1.4.1.2699.2.4.1.18.3.0

Integer R

Note 1:
a) If there is no any current alert, all of OID in alert table will respond default value.
pdmAlertGroupType =” “
pdmAlertGroupID = 0
pdmAlertSeverity = other (1)
The reset Object will respond default.

b) If there is FAN alert happen, the tables is shown below.
pdmAlertGroupType =” Fan”
pdmAlertGroupID = “Fan Error”
pdmAlertSeverity = Critical (3)
The rest Object will respond default.

c) If there is Lamp fail alert happen, the tables is shown below.
pdmAlertGroupType = “Lamp”
pdmAlertGroupID= Lamp Fail
pdmAlertSeverity = Critical (3)
The rest Object will respond default.

d) If there is Lamp hours running out alert happen, the tables is shown below.
pdmAlertGroupType = “Lamp”
pdmAlertGroupID= Lamp hours running out
pdmAlertSeverity = warning (4)
The rest Object will respond default.

e) If there is Projector Over-heating alert, the tables is shown below.
pdmAlertGroupType = “ThermalSensor”
pdmAlertGroupID= “Projector Overheating”
pdmAlertSeverity = warning (4)
The rest Object will respond default.