Table 4, Mount point naming and storage enclosure mapping – Dell POWEREDGE R720 User Manual

Page 15

Advertising
background image

Microsoft SQL Server 2012 Fast Track Reference Configurations using PowerEdge R720 and PowerVault MD3620i

15

For Fast Track architectures, Dell recommends using mount points for the storage access rather than
using drive letters. It is also important to assign the appropriate LUN/volume and mount point names
to the configuration in order to simplify troubleshooting and performance analysis. The mount point
names should be assigned in such a way that the logical file system reflects the underlying physical
storage enclosure mapping. Table 4 shows the LUN and mount point names used for the specific
reference configuration and the appropriate storage layer mapping. All the logical volumes were
mounted to the

C:\FT folder.

Mount point naming and storage enclosure mapping

Table 4.

Storage

Array

Storage

Enclosure

Storage

Processor

Disk

Group

Logical

LUN

(volume)

Logical

Volume

Label

Logical

Array

Label

Full Volume Path

SA1

SE1

(Base)

1

1

1

SA1-SE1-

SP1-DG1-v1

PRI

C:\FT\PRI\

SA1-SE1-SP1-DG1-

v1

SA1

SE1

(Base)

2

2

2

SA1-SE1-

SP2-DG2-v2

PRI

C:\FT\PRI\

SA1-SE1-SP2-DG2-

v2

SA1

SE2

(Expansion)

1

3

3

SA1-SE2-

SP1-DG3-v3

PRI

C:\FT\PRI\

SA1-SE2-SP1-DG3-

v3

SA1

SE2

(Expansion)

2

4

4

SA1-SE2-

SP2-DG4-v4

PRI

C:\FT\PRI\

SA1-SE2-SP2-DG4-

v4

SA1

-

1

5

5

SA1-SE2-

SP1-DG5-v5

LOG

C:\FT\LOG\

SA1-SP1-DG5-v5

SA: Storage Array, SE: Storage Enclosure, SP: Storage Processors, DG: Disk Group, V: Volume

Advertising
This manual is related to the following products: