Dell POWEREDGE M1000E User Manual

Page 13

Advertising
background image

Fabric OS Documentation Updates

7

53-1002063-03

bufOpMode

3

To display current buffer optimized mode for a single slot

switch:admin> bufopmode --show 12

Slot 12: buffer optimized mode - On

To enable buffer optimized mode for a given slot:

switch:admin> bufopmode --set 11

The operation is not supported when the slot is online

switch:admin> bufopmode --reset 12

The operation is not supported when the slot is online

switch:admin> slotpoweroff 11

switch:admin> slotpoweroff 12

switch:admin> bufopmode --set 12

Buffer optimized mode is turned on for slot 11

switch:admin> bufopmode --reset 12

Buffer optimized mode is turned off for slot 12

switch:admin> slotpoweron 11

switch:admin> slotpoweron 12

To display the changes:

switch:admin> bufopmode --showall

Slot 1: buffer optimized mode - Off

Slot 2: buffer optimized mode - Off

Slot 3: buffer optimized mode - Off

Slot 4: buffer optimized mode - Off

Slot 9: buffer optimized mode - Off

Slot 10: buffer optimized mode - Off

Slot 11: buffer optimized mode - On

Slot 12: buffer optimized mode - Off