Back-panel features and indicators – Dell PowerEdge 1750 User Manual

Page 9

Advertising
background image

 

If the optional RAID on motherboard (ROMB) card is activated, two indicators on each of the hard-drive carriers provide information on the status of the SCSI

hard drives. See

Figure 1

-3

and

Table 1

-3

. The SCSI backplane firmware controls the drive power

-on/fault indicator.

Figure 1-3. SCSI Hard-Drive Indicators

 

 

Table 1

-3

lists the drive indicator patterns. Different patterns are displayed as drive events occur in the system. For example, if a hard-drive fails, the "drive

failed" pattern appears. After the drive is selected for removal, the "drive being prepared for removal" pattern appears, followed by the "drive ready for
insertion or removal" pattern. After the replacement drive is installed, the "drive being prepared for operation" pattern appears, followed by the "drive online"
pattern.

 

 

Table 1-3. Hard-Drive Indicator Patterns 

Back-Panel Features and Indicators

 

Figure 1

-4

shows the controls, indicators, and connectors located on the system's back panel.

 

Figure 1-4. Back-Panel Features and Indicators

 

NOTE:

If the optional ROMB card is not installed, only the "drive online" indicator pattern appears. The drive-activity indicator also blinks when the drive

is being accessed.

Condition

Indicator Pattern

Identify drive

The green power-on/fault indicator blinks four times per second.

Drive being prepared for removal

The green power-on/fault indicator blinks two times per second.

Drive ready for insertion or removal Both drive indicators are off.

Drive being prepared for operation The green power-on/fault indicator is on.

Drive predicted failure

The power-on/fault indicator slowly blinks green, amber, and off.

Drive failed

The amber power-on/fault indicator blinks four times per second.

Drive rebuilding

The green power-on/fault indicator blinks slowly.

Drive online

The green power-on/fault indicator is on.

NOTE:

Connect the power cable to connector PS1 if your system only has one power supply. See Figure 1-4.

Advertising