Cabling the Dell™ PowerEdge™ R610 

 

 

Page 3 

 

2.2 Route the Power Cables through the Strain Reliefs 

After the tray and cables are installed, route the power cables through the strain reliefs located on the power 
supply handles as shown in Figure 2. 

Figure 2:  Routing Power Cables through the Strain Reliefs 

 

 

 

 

 

 

 

2.3 Routing the Cables through the CMA 

NOTE:  The CMA can be installed on either the right or left rear side of the rails. Mounting the CMA on the side 
opposite the power supplies (left side mount) is recommended; otherwise, the CMA must be disconnected in order 
to remove the outer power supply. Refer to “Replacing a Power Supply on a PowerEdge R610 with CMA” later in 
this white paper for details on power supply replacement. 

NOTE:  For guidelines on how to route cables within the rack, refer to the Dell White Paper “Best Practices Guide 
for Rack Enclosures”. 

Left Side Mounting Instructions 
1. Install the CMA on the left rear side of the rails by attaching both CMA housings to the attachment brackets on 

the rails. See Figure 3. 

2. Route the cables through the CMA while keeping any twisting of the cables to a minimum. Use the hook and 

loop straps on the CMA to secure the cables. 

 

 