Reinstallation error message remains on the lcd – Dell Powervault NX400 User Manual

Page 7

Advertising
background image

Error: -5005 Occurred While Creating An Operating System Volume

Description

Drives in expected operating system slots have existing foreign configurations.

Workaround

To work around this issue, enter the PERC BIOS during the operating system boot operation
and ensure that there are no foreign configurations, no data on the drives, the drives meet the
minimum size requirement, and are fully functioning and accessible.
For more information, see the PERC documentation at dell.com/support/manuals.

Error: -5006 Occurred While Creating An Operating System Volume

Description

Unable to locate the PowerVault operating system reinstallation media.

Workaround

To work around this issue, perform one of the following steps:

Ensure that the operating system reinstallation media is loaded in the optical drive. If

the media is present in the drive, the drive may be faulty.
For information about troubleshooting the drive, see the

Owner’s Manual

at dell.com/

support/manuals.

Ensure that the drive is still functional. Reboot the PowerVault NAS using the operating

system reinstallation media to restart the process.

Error: -5007 Occurred While Creating An Operating System Volume

Description

A pre-existing virtual disk with LUN ID 0 that is not being used for the NAS operating system
has been encountered. The operating system on the PowerVault NAS system must be on
virtual disk 0.

Workaround

To work around this issue, delete the current virtual disk with LUN ID 0 for the operating
system reinstallation to proceed.

1. Backup all data on virtual disk 0 if possible.
2. Reboot your system and boot into the PERC controller BIOS during Power On Self Test

(POST).
For more information about booting into the PERC controller BIOS, see the

PERC User’s

Guide

at dell.com/support/manuals.

3. Delete the virtual disk with LUN ID 0.
4. Reboot the PowerVault NAS system using the operating system reinstallation media.

Reinstallation Error Message Remains On The LCD

Description

The last error message remains on the LCD until the operating system is successfully
reinstalled.

Workaround

To work around this issue,

1. Change the user defined string to the default option or User Defined String.
2. Enter the BIOS and select the Embedded Server Management screen.

7