MP-235

pdmAlertAllAlertsCount

1.3.6.1.4.1.2699.2.4.1.18.3.0

INTEGER

R

AllAlertsCount=
FanErrorCounter+TempSwitchErrorCounte
r+TempSensorErrorCounter+LightSourceE
rrorCounter

The rest Object will respond default.

c) If there is Lamp fail alert happen, the tables is shown below
pdmAlertGroupType = “Lamp”
pdmAlertGroupID= Lamp Fail
pdmAlertSeverity = Critical (3)
The rest Object will respond default.

d) If there is Lamp hours running out alert happen, the tables is shown below
pdmAlertGroupType = “Lamp”
pdmAlertGroupID= Lamp hours running out
pdmAlertSeverity = warning (4)
The rest Object will respond default

e) If there is Projector Over-heating alert, the tables is shown below
pdmAlertGroupType = “ThermalSensor”
pdmAlertGroupID= “Projector Overheating”
pdmAlertSeverity = warning (4)
The rest Object will respond default.

f) If there is Lamp Over-heating alert, the tables is shown below
pdmAlertGroupType = “ThermalSwitch”
pdmAlertGroupID= “Lamp Overheating”
pdmAlertSeverity = Critical (3)
The rest Object will respond default.

pdmAlert