Dell PowerVault 221S (SCSI) User Manual

Page 27

Advertising
background image

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS

VER A02

PAGE 27

11/17/2005

• Table

4-2: PV22xS Configuration Topologies Vs RAID Level Performance

PV22xS Configuration Topologies

RAID Levels

Joined Split

Cluster

RAID 0

Default RAID 0
performance

Best performance, if
configured across multiple
channels

Similar to Joined
topology

RAID 1

Default

Increased Availability, if
mirror set is on separate
channel

Default

RAID 5

Default Default

Default

RAID 10

Default

Higher performance than
RAID 1 with same increased
availability

Default

RAID 50

Default

Increase availability, if
spanned across separate
channels

Default

It can be observed that selection of a PV22xS configuration topology impacts not only
Application Attributes but also impacts RAID level performance. Besides these
configuration topologies, PV22xS provides some common capabilities as listed below for
the storage solution:

Redundancy Capabilities

Physical SCSI Data Path Redundancy

PV22xS using two Enclosure Management Modules (EMM) provides redundant
data path when configured in Cluster topology.

Management Redundancy

With multiple EMMs in PV22xS, hardware redundancy is provided when servicing
enclosure management requests

Power Supply Redundancy

PV22xS is capable of running on single power supply; multiple power supplies
provide 1+1 redundancy

Cooling Redundancy

PV22xS provides support of up to 2 fan units; each fan unit has 2 blowers in all
making 4 fan blowers. The unit is thermally designed to continue operating with 1
of 4 fan blower failure, thus giving a 3+1 cooling redundancy

Reliability Capabilities

Thermal Reliability

Advertising
This manual is related to the following products: