Dell POWEREDGE R720XD User Manual

Dell Computers

Advertising
background image

02 - 2013

 

Statement of Volatility – Dell PowerEdge R720 and
R720XD

Dell PowerEdge R720 and R720XD contain both volatile and non-volatile (NV) components. Volatile
components lose their data immediately upon removal of power from the component. Non-volatile components
continue to retain their data even after the power has been removed from the component. Components chosen
as user-definable configuration options (those not soldered to the motherboard) are not included in the Statement
of Volatility. Configuration option information (pertinent to options such as microprocessors, remote access
controllers, and storage controllers) is available by component separately. The following NV components are
present in the PowerEdge R720 and R720XD servers.

 

Item

Non-Volatile
or Volatile

Quantity

Reference Designator

Size

Planer

  

 

PCH Internal CMOS
RAM

Non-Volatile 1

U_PCH

256

Bytes

BIOS SPI Flash

Non-Volatile

1

U_SPI_BIOS

8 MB

iDRAC SPI Flash

Non-Volatile

1

U_IDRAC_SPI

4 MB

BMC EMMC

Non-Volatile

1

U_EMMC

4 GB

CPU Vcore and VSA
Regulators

Non-Volatile

2

U11, U12

4.25 KB

System CPLD RAM

Volatile

1

U_CPLD

1 KB

System Memory

Volatile

Up to 12
per CPU

CPU<2:1>_CH<3:0>_D<2:0>

Up to 32GB per DIMM

Internal USB Key

Non-Volatile

Up to 1

N/A

Varies (not factory
installed)

Trusted Platform
Module (TPM)

Non-Volatile 1

U_TPM

128

Bytes

Power Supplies

PSU FW

Non-Volatile

1 per
PSU

Varies by part number

Up to 2MB. Varies by
part number

8x2.5" Backplane

SEP internal flash

Non-Volatile

1

U_SEP

Flash:32KB+4KB
EEPROM: 1KB

Advertising
This manual is related to the following products: