Dell PowerEdge C2100 User Manual
Page 13

Getting Started With Your System
11
Power
AC power supply (redundant)
Wattage
750 W
Voltage
100–240 VAC, 50/60 Hz, 9.5–5.0 A
Heat dissipation
2217.8 BTU/hr maximum
Maximum inrush current
Under typical line conditions and over
the entire system ambient operating range,
the inrush current may reach 55 A per power
supply for 10 ms or less.
Batteries
System battery
CR 2032 3.0-V Lithium coin cell
ROMB battery (optional)
3.7-V Lithium ion battery pack
Physical
Height
87.5 cm (3.44")
Width
43.74 cm (17.22")
Depth
72.2 cm (28.42")
Weight (maximum configuration)
28.5 kg (62.8 lb)
Weight (empty)
12 kg (26.5 lb)
Environmental
For additional information about environmental measurements for specific system
configurations, see
www.dell.com/environmental_datasheets.
Temperature
Operating
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
NOTE:
For altitudes above 2950 ft,
the maximum operating temperature
is derated 1ºF/550 ft.
Storage
–40° to 65°C (–40° to 149°F) with
a maximum temperature gradation
of 20°C per hour