Dell Poweredge FC630 User Manual

Dell Computer hardware

Advertising
background image

Dell - Internal Use - Confidential
Dell - Internal Use - Confidential

02 - 2013

Statement of Volatility – Dell PowerEdge M630/FC630

Dell PowerEdge M630/FC630 contains both volatile and non-volatile (NV) components. Volatile components
lose their data immediately upon removal of power from the component. Non-volatile components continue to
retain their data even after the power has been removed from the component. Components chosen as user-
definable configuration options (those not soldered to the motherboard) are not included in the Statement of
Volatility. Configuration option information (pertinent to options such as microprocessors, remote access
controllers, and storage controllers) is available by component separately. The following NV components are
present in the PowerEdge M630/FC630 server.

Item

Non-Volatile
or Volatile

Quantity

Reference Designator

Size

Planer

PCH Internal CMOS
RAM

Volatile

1

U_WBGA

256 Bytes

BIOS SPI Flash

Non-Volatile

1

U_SPI_BIOS1

16 MB

iDRAC SPI Flash

Non-Volatile

1

U_IDRAC_SPI1

4 MB

BMC EMMC

Non-Volatile

1

U_EMMC1

4 GB

BMC Memory

Volatile

1

U_IDRAC_MEM

2 Gb

CPU Vcore and
Memory regulator

Non-Volatile

6

PU51, PU66, PU71, PU58,

PU76, PU81

System CPLD

Non-Volatile

1

U_CPLD

2210 logic elements

1700 marcocells

272 IOs

System Memory

Volatile

Up to 12
per CPU

CPU1: DIMMA1~DIMMA12,

CPU2: DIMMB1~DIMMB12

Up to 32GB per DIMM

M630 2x2.5" SATA
Backplane

SEP internal flash

Non-Volatile

1

U_SEP1

Flash: 32KB

EEPROM: 16KB

M630 2x2.5" SAS
Backplane

SEP internal flash

Non-Volatile

1

U_SEP1

Flash: 32KB

EEPROM: 16KB

Advertising