Dell PowerEdge R730 User Manual

Page 9

Advertising
background image

Dell - Internal Use - Confidential

2x2.5" Backplane

SEP internal
flash

I2C interface via iDRAC

Program write protect
bit

Not user clearable

Backplane
External FRU

Programmed at ICT during
production.

Not WP

Cannot be cleared with existing tools
available to the customer

4x3.5" Backplane

SEP internal
flash

I2C interface via iDRAC

Program write protect
bit

Not user clearable

Backplane
External FRU

Programmed at ICT during
production.

Not WP

Cannot be cleared with existing tools
available to the customer

24x2.5" EXP/Backplane

NVSRAM
memory

Common Flash memory
Interface (CFI)

Hardware strapping

Not user clearable

Flash memory

Common Flash memory
Interface (CFI)

Hardware strapping

Not user clearable

Expander FRU
image

I2C interface via expander Hardware strapping

Not user clearable

BP FRU image

I2C interface via iDRAC

Hardware strapping

Not user clearable

16x2.5" EXP/Backplane

NVSRAM
memory

Common Flash memory
Interface (CFI)

Hardware strapping

Not user clearable

Flash memory

Common Flash memory
Interface (CFI)

Hardware strapping

Not user clearable

Expander FRU
image

I2C interface via Expander Hardware strapping

Not user clearable

BP FRU image

I2C interface via iDRAC

Hardware strapping

Not user clearable

8x2.5" Backplane

SEP internal
flash

I2C interface via iDRAC

Program write protect
bit

Not user clearable

8x3.5" Backplane

SEP internal
flash

I2C interface via iDRAC

Program write protect
bit

Not user clearable

Backplane
External FRU

Programmed at ICT during
production.

Not WP

Cannot be cleared with existing tools
available to the customer

Advertising