Bmc ip address error messages – Dell PowerEdge 7250 User Manual

Page 10

Advertising
background image

10

Information Update

www

.dell.com | support.dell.com

Red Hat Enterprise Linux AS 3 Operating System

Perform the following steps to recover the boot options:

1

From the EFI Boot Manager, select Boot option maintenance menu.

2

Select Add a Boot Option.

3

Select a volume.

4

Select the directory for the EFI partition.

5

Select the Red Hat directory.

6

Select elilo.efi.

7

Select N from Edit Existing Boot Option or make a new entry.

8

At the Enter New Description prompt, type

RHEL 3 AS

(or the name of the operating

system).

9

Under New BootOption Data, select the BootOption Data Type. Selections include ASCII,
Unicode, or No Boot Option.
Type the first character for the option you want to select or press <Enter> to select the
default. The default is Unicode.

10

At the Enter BootOption Data prompt, type

RHEL 3 AS

(or the name of the operating

system).

11

Type

Y

to save the changes.

12

Reboot the system for the changes to take effect.

BMC IP Address Error Messages

The Baseboard Management Controller (BMC) may issue error messages similar to the following
message if the DHCP server IP address is not assigned.

Invoking PXEDhcp4 to obtain IP address

Performing PXEbc sequence to obtain IP address

Error in PXEBaseCodeInterface --> Arp status return

8000000000000012

BMC IP Address configuration failed

To prevent these error messages, configure the DHCP server to assign a router IP address to the
PXE client, as in the following examples:

For systems using Windows Server 2003, Enterprise Edition, use the DHCP Manager to add a
scope option that assigns the router TCP/IP address for the PXE client automatically.

For systems using Red Hat Enterprise Linux AS 3, add the following line to the dhcpd.conf file:

options routers <

IP address of PXE server>-

Advertising