1

Introducing the SAN I/O Module

The Brocade 4424 is a 24-port Fibre Channel module with 8 external ports and 16 internal ports
designed for installation in a Dell PowerEdge M1000e Blade Server Enclosure. The product ships
with 12 ports enabled and can be upgraded to 24 ports through Ports on Demand (POD) licensing.
These ports support link speeds up to 4Gbit/sec.

Dual function and access gateway configurations

The SAN I/O Module ships in one of two configurations:

Dual Function configuration. In this configuration, the SAN I/O Module operates in Standard
Full Fabric Switch mode by default. The module can also operate in Access Gateway mode.

Access Gateway configuration. In this configuration the SAN I/O Module operates exclusively in
Access Gateway mode. Access Gateway simplifies SAN deployment by using NPIV. NPIV
provides Fibre Channel switch functions that improve SAN I/O Module scalability,
manageability, and interoperability. For more information on Access Gateway, refer to the
following:

-

For a list of SAN I/O Module F_Ports mapped to N_Ports in the SAN I/O Module as shipped
from the factory, refer to

“Access Gateway Mode default port mapping”

on page 25.

-

For general information and details on using Access Gateway, refer to the Brocade Access
Gateway Administrator’s Guide.

-

Since Access Gateway relies on NPIV technology for its connection to the edge fabric you
may have to prepare the edge fabric before connecting it to Access Gateway. Please refer
to the SAN TECH NOTE – Preparing to Install the Brocade Access Gateway for specific
instructions.

NOTE

When shipped in Access Gateway configuration, a Switch (Fabric) license is required to operate the
module in Standard Full Fabric Switch mode.

NOTE

Access Gateway cannot be connected directly into an array; it requires a fabric to support NPIV.

Determining module configuration

The factory configuration type is identified by the part number on a label attached to the module.
Refer to

Figure 3

on page 5 for label location.

If the part number is DL-4424-0001, then the SAN I/O Module is configured in Standard Full
Fabric Switch mode. Note that Full Fabric Switch mode is the default setting when shipped
from the factory. Access Gateway mode can also be enabled on this module.