Dell PowerVault MD3000 User Manual

Page 2

Advertising
background image

2

׀

Dell PowerVault Data MD3000 Support Matrix

Rule

First

Gen.

Second

Gen.

The management Ethernet part of the RAID controller
module must be connected to a switch port that is
configured to use Auto-Negotiate

√

√

Connecting an MD3000 and MD3000i to the same host is
supported.

√

Up to two MD1000 expansion enclosures can be attached
to the MD3000 for a total of 45 SAS and/or SATA physical
disks.

√

√

Attached MD1000 expansion enclosures must be run in
unified mode.

√

√

The enclosure can contain a mixture of SAS and SATA II
physical disks.

√

√

Do not mix SAS and SATA disks in a disk group.

√

√

A hot spare for a disk group must be a physical disk of equal
or greater size than any of the member disks.

√

√

The hot spare for a disk group with SAS physical disks must
be a SAS disk.

√

√

The hot spare for a disk group with SATA physical disks
must be a SATA disk.

√

√

When using out-of-band management with SMcli by
specifying the RAID Controller management port IP
addresses on the MD Storage Array, SMcli commands that
change the attributes of a virtual disk, virtual disk copy, or
snapshot virtual disk, must have management access to the
owning RAID Controller Module to complete. Where
applicable it is a best practice to specify both management
port IP addresses on the SMcli invocation: "SMcli
192.168.128.101 192.168.128.102 -c".

√

√

Only the Dell Linux MPP multi-path driver should be
loaded on a Linux host server***

√

√

MD3000 and MD3200 series supported on a single Linux
host.***

√

Dell MPP drivers are required for multi-path support (refer
to Table 8). Linux open framework dm-mpp (multi-path)
drivers are not supported with the MD3000.

√

√

Virtual disks on an MD3000 cannot be used for booting.

√

√

Maximum Virtual Disk Size cannot exceed 2 Terabytes.

√

Each virtual disk is limited to a maximum of 30 physical

√

Advertising