Dell PowerEdge 2800 User Manual

Page 3

Advertising
background image

Back to Contents Page

SCSI channels

Two 68-pin U320 SCSI

 

Video 

Video type

ATI Radeon 7000-M video controller; VGA connectors

Video memory

16 MB

 

Power 

AC power supply (per power supply)

Wattage

930 W

Voltage

85–264 VAC, autoranging, 47–63 Hz, 13.32 A

Heat dissipation

2697 BTU/hr maximum

Maximum inrush current

Under typical line conditions and over the entire
system ambient operating range, the inrush current
may reach 25 A per power supply for 10 ms or less.

Batteries

 

System battery

CR 2032 3.0-V lithium ion coin cell

ROMB battery (optional)

4.1-V lithium ion

 

Physical 

Rack

 

Height

21.79 cm (8.580 in)

Width

48.03 cm (18.908 in)

Depth

71.13 cm (28.002 in)

Weight (maximum configuration)

45.36 kg (100 lb)

Tower (without bezel)

 

Height

48.55 cm (19.113 in)

Width

30.15 cm (11.869 in)

Depth

69.58 cm (27.392 in)

Weight (maximum configuration)

48.98 kg (108 lb)

 

Environmental 

 

NOTE:

For additional information about environmental measurements for specific system configurations, see

www.dell.com/environmental_datasheets.

Temperature

Operating

10° to 35°C (50° to 95°F)

Storage

–40° to 65°C (–40° to 149°F)

Relative humidity

Operating

8% to 85% (noncondensing) with a maximum
humidity gradation of 10% per hour

Storage

5% to 95% (noncondensing)

Maximum vibration

Operating

0.25 G at 3–200 Hz for 15 min

Storage

0.5 G at 3–200 Hz for 15 min

Maximum shock

Operating

One shock pulse in the positive z axis (one pulse on
each side of the system) of 41 G for up to 2 ms

Storage

Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse on
each side of the system) of 71 G for up to 2 ms

Altitude

Operating

16 to 3048 m (–50 to 10,000 ft)

Storage

16 to 10,600 m (–50 to 35,000 ft)

Advertising