Dell PowerVault DX6112 User Manual

Page 118

Advertising
background image

Error Code

Message Information

Details

System performance may be degraded.

Action

Check the system operating environment, including airflow and inlet
temperature. Check system logs for temperature and thermal
component failures.

PSU0034

Message

An under voltage fault detected on power supply <

number

>.

Details

This failure may be the result of an electrical issue with cables or
subsystem components in the system.

Action

1. Remove and reinstall the power supply.
2. Check cables and subsystem components in the system for

damage.

3. If the issue persists, see

Getting Help

.

PSU0035

Message

An over voltage fault detected on power supply <

number

>.

Action

Check input power or reinstall the power supply. If the issue persists,
see

Getting Help

.

PSU0036

Message

An over current fault detected on power supply <

number

>.

Details

This failure may be the result of an electrical issue with cables or
subsystem components in the system.

Action

1. Remove and reinstall the power supply.
2. Check cables and subsystem components in the system for

damage.

3. If the issue persists, see

Getting Help

.

PSU0037

Message

Fan failure detected on power supply <

number

>.

Action

Check for fan blockage. If the problem persists, see

Getting Help

.

PSU0076

Message

A power supply wattage mismatch is detected; power supply
<

number

> is rated for <

value

> watts.

Details

Power supplies should be of the same input type and power rating.

Action

Install matched power supplies and review this manual for proper
configuration.

PSU1201

Message

Power supply redundancy is lost.

118

Advertising