Introduction: Dell PowerVault 220S and 221S Systems User's Guide

file:///C|/Users/rishi_sood/Desktop/220s/en/ug/8f182c11.htm[3/7/2013 12:09:43 PM]

Power Supply/Cooling Modules

Your system supports two combined power supply and cooling modules. While the system is designed to operate normally

with only one functional power supply, both cooling modules (with two blowers each) must be present for proper cooling. If

only one power supply is needed, a blank must be inserted into the other slot to mount the second cooling module.

The power supply blank has the capacity to transfer power and control signals to and from the cooling module. In this

nonredundant power-supply configuration, the cooling modules operate at higher speeds to maintain proper system cooling

and produce a higher acoustical noise than in the redundant power-supply configuration.

If one blower within a cooling module fails, your system reverts to a nonredundant fan configuration. The remaining three

blowers in the two cooling modules operate at higher speeds to maintain proper system cooling and produce higher acoustical

noise than in the redundant fan configuration (with four blowers in two cooling modules).

CAUTION:

The system will operate for only five minutes with one cooling module installed. This allows you

the necessary time to replace a failed cooling module. If both cooling modules are installed, the system

will still operate if a single blower fails. While it is rare for more than one blower to fail simultaneously, if

this event occurs, the system may shut down to prevent overheating.

The cooling module is securely mounted to the power supply using a hook-and-latch fastener. This simplifies the removal and

installation of cooling modules and power supplies.

Table 1-7

lists the function of each power supply and cooling module LED indicator. See

Figure 1-7

for the location of the LED

indicators.

Table 1-7. Power Supply/Cooling Module LED Indicators

Module

Icon

LED Indicator

LED

Icon

Function

Power supply

Power on (green)

DC output voltages are within specifications.

Fault (amber)

One of the DC output voltages is not within specifications.

AC status (green)

AC input voltage is within specifications regardless of the position of the

power switch.

Cooling

module

Blower A fault

(amber)

Cooling module blower A has failed.

Blower B fault

(amber)

Cooling module blower B has failed.

Figure 1-7. Power Supply and Cooling Module LED Features and Indicators