Dell PowerEdge M910 User Manual

Page 10

Advertising
background image

Power — Enclosure

Heat dissipation

NOTE: Heat dissipation is calculated using the

power supply wattage rating.

1200 BTU/hr (maximum)

Maximum inrush current

Under typical input voltage conditions and over the

entire system ambient operating range, the inrush

current may reach 55 A per power supply for 10 ms or

less.

System Voltage Requirements

NOTE: This system is also designed to be connected to

IT power systems with a phase to phase voltage not

exceeding 230 V.

16 A, 200 V AC to 240 V AC, 50 Hz/60 Hz (3000 W power

supply)
16 A, 100 V AC to 240 V AC, 50 Hz/60 Hz (2700 W power

supply)

DC/DC power supply (per power supply module)

Wattage

2700 W

Connector

Molex # 394260002 at PSU end,
mating connector Molex # 39422-0012

Heat dissipation

1205 BTU/hr (maximum)

Maximum inrush current

Under typical input voltage conditions and over the

entire system ambient operating range, the inrush

current may reach 120 A per power supply for 10 ms or

less.

System Voltage Requirements

75 A, 48 V DC to 60 V DC

NOTE: Heat dissipation is calculated using the power

supply wattage rating.

Physical — Blades

PowerEdge M915

Height

38.5 cm (15.2 inch)

Width

5 cm (2 inch)

Depth

48.6 cm (19.2 inch)

Weight (maximum)

12.7 kg (28 lb)

PowerEdge M910

Height

38.5 cm (15.2 inch)

Width

5 cm (2 inch)

Depth

48.6 cm (19.2 inch)

Weight (maximum)

13.1 kg (29 lb)

PowerEdge M820

Height

38.5 cm (15.2 inch)

Width

5 cm (2 inch)

10