• To help prevent electric shock, plug the system and peripheral power cables into properly

grounded electrical outlets. These cables are equipped with three-prong plugs to help ensure

proper grounding. Do not use adapter plugs or remove the grounding prong from a cable.

• Observe extension cable and power strip ratings. Make sure that the total ampere rating of all

products plugged into the power strip does not exceed 80 percent of the ampere ratings limit

for the power strip.

• To help protect your system from sudden, transient increases and decreases in electrical

power, use a surge suppressor, line conditioner, or uninterruptible power supply (UPS).

• Position system cables and power cables carefully. Route cables so that they cannot be stepped

on or tripped over. Be sure that nothing rests on any cables.

• Do not modify power cables or plugs. Consult a licensed electrician or your power company

for site modifications. Always follow your local/national wiring rules.

Rack Mounting of Systems

• Refer to the rack installation documentation accompanying the rack for specific caution

statements and procedures.

• System rack kits are intended to be installed in a rack by trained service technicians. If a non-

Dell rack is utilized, be sure that the rack meets the specifications of a Dell rack.

• Elevated Ambient Temperature: If installed in a closed rack assembly, the operation

temperature of the rack environment may be greater than room ambient. Use care not to

exceed the rated maximum ambient temperature of the unit.

• Reduced Air Flow: Installation of the equipment in a rack should be such that the amount of

airflow required for safe operation of the equipment is not compromised.

• Mechanical Loading: Mounting of the equipment in the rack should be such that a hazardous

condition is not achieved due to uneven mechanical loading.

• Circuit Overloading: Consideration should be given to the connection of the equipment to

the supply circuit and the effect that overloading of circuits might have on overcurrent

protection and supply wiring. Consider equipment nameplate ratings for maximum current.

• Reliable Earthing: Reliable earthing of rack mounted equipment should be maintained. Pay

particular attention to supply connections other than direct connections to the branch circuit

(for example, use of power strips).