System Messages

 

 

 

1-2-3  DMA page register read/write failure

 

3-1-1  Slave DMA register failure

 

3-1-2  Master DMA register failure

 

3-1-3  Master interrupt mask register failure

 

3-1-4  Slave interrupt mask register failure

 

3-2-2  Interrupt vector loading failure

 

3-2-4  Keyboard Controller Test failure

 

3-3-1  NVRAM power loss

 

3-3-2  NVRAM configuration

 

3-3-4  Video Memory Test failure

 

3-4-1  Screen initialization failure

 

3-4-2  Screen retrace failure

 

3-4-3  Search for video ROM failure

 

4-2-1  No time tick

 

4-2-2  Shutdown failure

 

4-2-3  Gate A20 failure

 

4-2-4  Unexpected interrupt in protected mode

 

4-3-3  Timer-chip counter 2 failure

 

4-3-4  Time-of-day clock stopped

 

4-4-1  Serial or parallel port test failure

 

4-4-4  Cache test failure

NOTE:

If the message you received is not listed in the following table, see the documentation for either the operating system or the program that was

running when the message appeared.

Message

Possible Cause

Corrective Action

 8042 Gate-A20 error

 

The keyboard controller failed its test.

 

If you receive this message after you make changes in the

system setup

program

, enter the system setup program and restore the original value(s).

 Address Line Short!

 

An error in the address decoding circuitry in the

memory has occurred.

 

Reseat the memory modules

.

 C: Drive Error

 C: Drive Failure

 

The hard drive is not working or is not configured

correctly.

 

Ensure that the drive is installed correctly in the computer and defined

correctly in the

system setup program

.

 Cache Memory Bad, Do
Not Enable Cache

 

The cache memory is not operating.

 

See "Contacting Dell" in your Owner's Manual for instructions on obtaining

technical assistance.

 CH-2 Timer Error

 

An error is occurring on the timer on the system

board.

 

See "Contacting Dell" in your Owner's Manual for instructions on obtaining

technical assistance.

 CMOS Battery State
Low

 CMOS Checksum Failure

 CMOS System Options
Not Set

 CMOS Display Type
Mismatch

 CMOS Memory Size
Mismatch

 CMOS Time and Date
Not Set

 

The system configuration information in the system

setup program is incorrect or the battery charge
may be low.

 

Enter the system setup program

, verify the system configuration, and then

restart the computer.

 Diskette Boot Failure

 

Drive A or B is present but has failed the BIOS

POST.

 

Ensure that the drive is installed correctly in the computer and defined

correctly in the

system setup program

. Check the interface cable at both

ends.

 DMA Error

 DMA 1 Error

 DMA 2 Error

 

Error in the DMA controller on the system board.

 

The keyboard or

system board

may need to be replaced.

 FDD Controller
Failure

 

The BIOS cannot communicate with the floppy drive

or hard drive controller.

 

Ensure that the floppy drive or the

hard drive

is installed correctly in the

computer and defined correctly in the

system setup program

. Check the

interface cable at both ends.