SR870BN4 Error Reference Guide

Beep Codes

Revision 1.0

31

8. Beep

Codes

During the course of executing POST, there are occassions where fatal problems happen
before video is enabled. These fatal errors are conveyed with the use of the speaker via
encoded beeps, coupled with post debug codes.

Since the duration of the display-less POST execution is relatively short, there are fewer beep
codes than displayed error codes.

In order to extend the useful range of the beep codes, without the need to have dozens of
codes, the beeps are classified and the distinction within class is made via the post debug card.

Table 14. Error Beep Codes

Beeps Error

message

Description

3 Memory

failure

Memory

test failure. See table below for additional error

information.

4

System timer

System timer is not operational.

5

Processor failure

Processor failure detected.

7

Processor exception interrupt error

The processor generated an exception interrupt.

8

Display memory read/write error

The system video adapter is either missing or its memory
is faulty. This is not a fatal error.

9

ROM checksum error

System BIOS ROM checksum error.

11

Invalid BIOS

General BIOS ROM error.

Table 15. POST Memory Beep Error Codes – Debug Port Encoding List

Beep
Code

Debug port error code (lower
byte of North I2C debug display)

Meanings

3

CF9Fh

No valid memory was found in the system.

3

CF64h

Mismatched DIMMs in a row, and no valid memory to
boot.

8.1.1

Memory Test Failure

8.1.1.1

No Memory Found in the System

This indicates that the memory test has found no valid memory in the system. The system will
not boot. An SEL log entry will be made in this case.

8.1.1.2

Mismatched DIMMs Within Single Row Populated

This indicates that only a single row is populated, and that row contains mismatched DIMMs,
preventing booting. An SEL log entry will be made in this case.