Dell PV745N Release Notes

file:///T|/htdocs/stor-sys/spv745N/en/RN/RelNotes.htm[12/5/2012 10:17:35 AM]

program. To disable the BIOS of the PERC RAID controller, use the RAID controller’s BIOS
Configuration Utility. See your PERC documentation for more information


===============================================================
Updated System Depth
===============================================================
Issue:
The system depth documented in your system’s User's Guide is incorrect. The correct depth
of the system with the optional bezel is 63.0 cm (24.8 inches)


===============================================================
Using DSET to Access System Information
===============================================================
DSET is a Dell-developed tool that allows you to access information about system components,
firmware, and driver versions. After every reinstall, a DSET report is automatically generated for
your NAS system.

NOTE: When you update system components such as drivers or firmware, you must generate a
new DSET report to reflect these updates.

To create a DSET report, use a keyboard, monitor, and mouse connected to your NAS system
to log in, or log in remotely using Terminal Services. At the command prompt, enter the following
command:

C:\Program Files\Dell\DSET\bin\systeminfo.bat


===============================================================
Found New Hardware Window Displays During Reinstallation
===============================================================
Problem:
During reinstallation, a Found New Hardware window may display, prompting you to restart
the system.

Cause:
In a previous boot, the operating system disk was upgraded to dynamic.

Solution:
Ignore the window, and select No. The system restarts automatically after it has completed the
reinstallation. Take no other action.


===============================================================
Enabling the Screen Saver with Windows Storage Server 2003
===============================================================
Problem:

In the Microsoft

®

Windows

®

Storage Server 2003 operating system, you cannot enable the screen

saver in the Display Properties dialog of the Control Panel.

Cause:
The screen saver is disabled by default on your NAS system.