Machine pit layout, Troubleshooting – Chief Manufacturing Pit Boss 638699 User Manual

Page 19

Advertising
background image

PIT BOSS

Users Manual

17

Machine Pit Layout


The PIT BOSS is designed specifically for use in a flush mount pit. Figure 39 shows the pit dimensions. For maximum
effectiveness it is essential that the hydraulic and air lines be run in conduit under the surface of the floor. The conduit should
be 2” inside diameter and must be acceptable for the use with concrete. Where ever the conduit emerges will mark the
location of the pump and stand. Be certain this is an acceptable area clear of traffic. The profile of the PIT BOSS and
accessories is shown in Figure 26. Placement of the pit should take into account these accessories plus additional space
needed for a comfortable work area.

Figure 39

Troubleshooting

PROBLEM CAUSE

POSSIBLE SOLUTION

Pump will not Run

Air supply disconnected

Plug in air supply

Air supply not energized

Turn on air supply

Bad pump

Replace pump. Contact Chief Automotive Service Representative
for replacement.

Pump will not build
pressure or builds
pressure slowly

Hydraulic fluid low

Fill fluid reservoir to within 1” (25 mm) of top with SUS215 viscosity
@ 100°F (38C) 10W hydraulic oil with all cylinders down and
machine in loading position.

Contamination in fluid

Remove and clean fluid. Contact Chief Automotive Service
Representative.

Contamination in cylinders

Remove and inspect cylinders. (Refer to parts manual). Contact
Chief Automotive service representative.

Pump will not hold
pressure

Hydraulic oil leak

Check hoses, fittings, cylinders, and quick couplers for leaks.
Tighten or replace if necessary

Pump stalls or will not
start under pressure

Contamination in fluid

Remove and clean elbow fittings at cylinders. Contact Chief
Automotive Technologies Service Representative.

Too

much

weight


Insufficient air supply

Maximum total lift capacity (including 2000 lb Shop Hopper) is 8500
lbs.
Use different air supply.

Tower cylinder jumps

Air in hydraulic system

Bleed hydraulic system

Tower cylinder will not
extend

Auxiliary line valve closed

Open auxiliary line valve one turn

Auxiliary line not connected
to tower

Connect auxiliary line to tower

Lift switch turned on

Turn off lift switch

Pump will not build pressure

See pump problems above

Collars jump under load

Improper fit between collar
and tower pipe

Refit collar – Contact Chief Automotive service representative.