Conclusion, Table 7, Recommended bios setting – Dell PowerEdge 1655MC User Manual

Page 26

Advertising
background image

Optimal BIOS settings for HPC with Dell PowerEdge 12

th

generation servers

26

shows the performance improvement with the new cluster relative to the previous generation. The
secondary y-axis plots the energy efficiency of the new cluster relative to the earlier one.

The results are impressive. HPL performance is 3.6 times (3.6x) better with the latest generation and
2.93 times more energy efficient. Fluent and WRF also demonstrate a significant improvement with the
new servers. For applications that are similar to LU, the two generations perform similarly. While
comparing energy efficiency, recall that the 12

th

generation cluster uses processors that are a higher

wattage than the 11

th

generation cluster (130W versus 95W).

7. Conclusion

The goal of this white paper is to provide quantitative data on the impact of different PowerEdge BIOS
options on the performance and energy efficiency of HPC applications. Unique to this study is the
emphasis not just on performance but also power consumption and energy efficiency, and the focus on
a cluster-level study as opposed to a single-server evaluation.

Table 7. Recommended BIOS setting

Balanced
configuration

Performance
focused

Energy Efficient
configuration

Latency
sensitive

10

System Profile

Performance Per
Watt Optimized
(DAPC)

Performance
Optimized

Performance Per
Watt Optimized
(DAPC)

Custom

CPU Power
Management

System DBPM

Max
Performance

System DBPM

Max
Performance

Memory
Frequency

Max
Performance

Max
Performance

Max Performance

Max
Performance

Turbo Boost

Enabled

Enabled

Disabled

Disabled

C States

Enabled

Disabled

Enabled

Disabled

C1E

Enabled

Disabled

Enabled

Disabled

Monitor/ Mwait

Enabled

Enabled

Enabled

Disabled

Logical
Processor

Disabled

Disabled

Disabled

Disabled

Node
Interleaving

Disabled

Disabled

Disabled

Disabled

* The text in gray indicates options that are pre-selected by the System Profile and cannot be tuned individually.
Text in black indicates options that should be explicitly configured.

Dell PowerEdge 12

th

generation servers have an enhanced BIOS that provides several options that can

be tuned to suit specific needs. This white paper evaluates some of these BIOS tuning parameters and
provides specific recommendations on the best settings for HPC applications.

Advertising