Dell POWERVAULT MD3620I User Manual

Page 21

Advertising
background image

Getting Started With Your System

19

RAID controller module

Eight single-color LEDs:

• One battery fault

• One cache active

• One controller fault

• One controller power

• One system identification

• One management Ethernet activity

• Two iSCSI IN port activity

Four two-color LEDs:

• Two iSCSI IN link speed

• One SAS OUT link or fault

• One management Ethernet link speed

Switch

System identification button

Located on the front control panel.
This button is used to locate a system
within a rack.

Enclosure mode switch

Located on the front of the system.
This switch is not applicable to the
PowerVault MD3600i series storage array.

Password reset switch

Located on the back panel of the RAID
controller module. This switch is used to
reset the storage array password.

Power Supplies

AC power supply (per power supply)

Wattage

600 W

Voltage

100–240 VAC (8.6 A–4.3 A)

Heat dissipation

100 W

Maximum inrush current

Under typical line conditions and over the
entire system ambient operating range,
the inrush current may reach a maximum of
55 A per power supply for 10 ms or less.

LED Indicators (continued)

Advertising
This manual is related to the following products: