A.3.2 tpim-f3 for single mode fiber – Cabletron Systems STHI User Manual

Page 71

Advertising
background image

Fiber Optic TPIM Specifications

Page A-4

A.3.2

TPIM-F3 for Single Mode Fiber

The TPIM-F3 connector supports Single Mode Fiber Optic cabling.

Transmitter Power decreases as temperatures rise. Use the Output Power
Coefficient (-0.15 dBm) to calculate increased or decreased power output
for the operating environment. For example, the typical power output at
25

°

C is -16.4 dBm. For a 4

°

C temperature increase, multiply the typical

coefficient (-0.15 dBm) by four and add the result to typical output power:
(4 x -0.15 dBm + -16.4 = -17.0).

Figure A-4. Transmitter Power Levels

Table A-3. TPIM-F3 Specifications

Parameter

Typical

Minimum

Maximum

Transmitter

Peak Wave Length

1300 nm

1270 nm

1330 nm

Spectral Width

60 nm

–

100 nm

Rise Time

3.0 nsec

2.7 nsec

5.0 nsec

Receive

Sensitivity

dBm

Less Power

More Power

-40

-35

-30

-25

-20

-15

-10

-5

0

Maximum

Receive

Input Power

Transmitter Power*

(At 25

°

C into

8.3/125

µ

m fiber)

Minimum Sensitivity (-30.0)

Typical Sensitivity (-31.0)

Maximum Sensitivity (-36.0)

Maximum Receive Input (-6.99)

Typical Receive Input (-7.5)

Minimum Receive Input (-9.72)

Maximum Transmit Power (-12.0)

Typical Transmit Power (-15.5)

Minimum Transmit Power (-21.0)

* Transmit Power Typical Power Minimum Power Maximum Power
Coefficient
(See Note Below)-0.15dBm/

°

C -0.12 dBm/

°

C-0.18 dBm/

°

C

Advertising