Example program, Crestron dm-md8x8 8x8 digitalmedia™ switcher – Crestron electronic DM-MD8X8 User Manual
Page 53

Crestron DM-MD8X8
8x8 DigitalMedia™ Switcher
To configure a SIMPL Windows program for this layout, drop
DM-RMC-100 devices onto the output cards that are on the DM-Switcher
as shown in the diagram below. The IP table of each DM-RMC-100 will be
automatically configured and uploaded.
DM-RMC-100s Placed on DMC-CATO-HD Outputs
• Scenario 2: Control Center with Control System and DM Switcher and
DM-RMC-100 Room Controller; Automatic IP Table Configuration
Control Center Containing Control System and DM Switcher Operating with
Classroom Containing Control System and DM-RMC-100 Room Controller
DM-MD8X8
DM-RMC-100
Ethernet
Ethernet
Ethernet
DMNet
CLASSROOM
CONTROL CENTER
CONTROL
SYSTEM
CONTROL
SYSTEM
To configure a SIMPL Windows program for this layout, drop
DM-RMC-100 devices onto the control system’s Ethernet slot. The IP table
of each DM-RMC-100 will require manual configuration.
Program Manager
Program Manager is the view where programmers “program” a Crestron control
system by assigning signals to symbols.
The symbol can be viewed by double clicking on the icon or dragging it into Detail
View. Each signal in the symbol is described in the SIMPL Windows help file (F1).
Example Program
An example program for the DM-MD8X8 is available from the Crestron website
(
Operations Guide – DOC. 6755A
8x8 DigitalMedia™ Switcher: DM-MD8X8
• 49