Crown Boiler CWI138 User Manual

Page 41

Advertising
background image

41

40

120 volts

across

terminals at

circulator?

Do burners

shut dow n before

gage temp

exceeds high limit

setting +15F?

Circulator

start?

120 volts at

C1&C2?

N

Remove t'stat or
zone valve end
sw itch w ires from
T&TV terminals on
L8124E. Install
temporary jumper
across terminals T
and TV.

Does

circulator
run now ?

*Defective
L8124E-see
Note 6 on page
36.

* Boiler w ater
temperature
has dropped
below low limit
setting

*Loose connection in t'stat or
zone valve end sw itch w iring

*Defective t'stat or zone
component

*T'stat or zone system
misw ired-consult t'stat or
zone valve manufacturer's
instructions

N

Do burner and

circulator shut

dow n at end of

call for heat?

END

Pull w ire off of T

terminal on

aquastat. Does

boiler shut dow n?

*T'stat or
zone valve
w iring calling
for heat

*T'stat w ires
shorted

* Boiler w ater
temperature
has dropped
below low limit
setting

*Internal boiler
w iring
problem,
consult Crow n
representative

*Defective
L8124E

*Sensing bulb not
bottomed out in
w ell

24 volts

across

T&TV?

*Seized or
defective
circulator

*Bad electrical
connection
betw een C1 or
C2 and
circulator

Y

N

Y

N

Y

N

Y

Y

Y

N

N

Y

Y

N

Main

burners

light?

*Boiler w ater
temperature
exceeds high limit
setting

* Defective
L8124E

Y

N