Chateau – Vermont Casting ChateauTM DVT38IN User Manual

Page 41

Advertising
background image

41

Chateau™

20011956

Pilot Flame Adjustment

Typically, the top 3/8” or 1/2” of the pilot flame sensor
should be engulfed in the pilot flame. (Page 33, Fig. 55)
To adjust pilot burner:
1. Locate pilot adjustment screw on the valve next to

the black plastic cap. Refer to Page 35.

2. Adjust pilot screw to provide proper sized flame.

Only a small adjustment should be needed.

NOTE: Do not rotate screw excessively. Do not adjust
any other screws on the valve.

Conversion to LP

Burner Orifice

Input (BTU/hr)

Kit #

Model

Front

Part #

Middle

Part #

Rear

Part #

Minimum Maximum

20011992

DVT38IP

#66

20009182

#59

20000664

#50

30000337

34,000

46,000

(.033”)

(.041”)

(.070”)

20012367

DVT44IP

#63

20006251

#57

20004587

#49

20006252

45,000

60,000

(.037”)

(.043”)

(.073”)

Table 1 Injector Orifice Size Matrix

Conversion to LP

Burner Tube

Burner Housing

Model

Air Shutter Setting

Air Shutter Setting

DVT38IP

Fully open

n/a

DVT44IP

Fully open

Fully open

Table 2 Air Shutter Settings

2

Table 3 Valve Minimum Rate Screw

Model

Size

Part #

DVT38IP

#31 (.120”)

20012364

DVT44IP

No Shank Screw

20012264

Advertising