01-G1014 Field Wiring Diagram

32

Doc 01-G0674

Rev E

IT IS IMPORTANT TO READ ALL SAFETY RULES INCLUDED IN THE INSTALLATION MANUAL BEFORE
BEGINNING INSTALLATION. FAILURE TO COMPLY WITH THE SAFETY INSTRUCTIONS MAY RESULT
IN SERIOUS PERSONAL INJURY OR PROPERTY DAMAGE.

NOTES:
1) REMOVE THIS JUMPER TO CAUSE GATE ARM TO CLOSE IMMEDIATELY WHENEVER IT IS OPENED, UNLESS A VEHICLE IS ON THE
HOLD OPEN LOOP. IF THIS JUMPER IS NOT REMOVED, ARM WILL REMAIN OPEN UNTIL A VEHICLE ENTERS AND EXITS THE HOLD
OPEN LOOP.

2) ADD JUMPER FROM TERMINAL #8 TO #9 WHENEVER CLOSE BUTTON IS USED. DO NOT USE WITH HOLD OPEN LOOP.

3) 115V UTILITY OUTLET (4 AMP MAX.) PROVIDED ON 115V MODELS ONLY.

4) SEE REVERSE SIDE FOR INTERNAL OPERATOR WIRING.

5) DO NOT CONNECT INPUT POWER LINES TO L1 & L2 TERMINALS. POWER LINES MUST BE CONNECTED TO THE POWER SWITCH.

DRAWING NO.:

01-G1014

FIELD WIRING

CONTROL WIRING

LOOP DETECTORS BY OTHERS

LINE VOLTAGE SUPPLY

RADIO CONTROL

MANUAL
OPEN

SEE
NOTE #1

SEE NOTE #2

SENSING EDGE

OPEN BUTTON

OR OTHER

OPEN CONTROL

CLOSE BUTTON

SEE NOTE #2

OPEN
LOOP

HOLD OPEN

LOOP

115V

ACCESSORIES

(0.2A MAX)

1 PHASE

INCOMING

LINE

LOOP WIRE CONNECTIONS FOR

FACTORY SUPPLIED (PLUG-IN)

DETECTORS ONLY

ELECTRICAL CABINET

ON

OFF

SWITCH

115V

OUTLET

SEE

NOTE #3

CONNECTIONS FOR LOOP DETECTORS

NOT SUPPLIED BY THE FACTORY

PRESENCE CONTACT OF

LOOP TO OPEN

PRESENCE CONTACT OF

LOOP TO HOLD OPEN

LOOP WIRES AND POWER FOR LOOP DETECTORS

SHOULD BE DIRECTLY WIRED TO DETECTOR ITSELF.

REFER TO INSTRUCTIONS ACCOMPANYING DETECTOR.

CONNECTIONS FOR STANDARD

3-WIRE 24 VAC RADIO CONTROL

RADIO CONTROL WILL OPEN GATE

AND REVERSE IF CLOSING. IT WILL

NOT STOP OR CLOSE THE GATE.

WARNING

(SEE NOTE #5)

(SEE NOTE #5)