Troubleshooting

Symptom

Remedy

Power

The POWER switch does not

function.

• Connect the AC power cord securely.

The power is turned on but the
VCR does not operate.

Moisture condensation occurs. Turn the power off, unplug the AC
power cord and leave the VCR to dry for over an hour.

Clock

The dock has stopped and

—"

lights in the display window.

The dock stops if the VCR is discormected from the wall outlet for

more than th^ hours. Reset the dock (and timer).

Playback

The playback picture does not

appear on the TV screen.

• Make sure the TV is set to the channel for the VCR. If you are using a

monitor, set it to video input

The picture is not clear.

• Adjust the tracking with the TRACKING NORMAL/SLOW buttons.
• The video heads are dirty (see below). Qean the video heads using the

Sony T-25CL video head cleaning cassette. If this deaning cassette is

not available in your area, have the heads deaned at your nearest Sony
service facility (a standard service charge will be required.) Do not use

a commerdally available wet-type deaning cassette, as it may damage

the video heads.

• The video heads may have to be replaced. Consult your local Sony

dealer for more information.

The picture rolls vertically

during picture search.

Adjust the vertical hold control on the TV or monitor.

The picture has

ik

> sound.

• The tape is defective. Use a new tape.

Symptoms

caused by contaminated video heads

« Normal picture

* Rough picture

• Undear picture

(continued)