EŒCTRICAL REQUIREMENTS AND SAP

ELECTRICAL REQUIREMENTS - conf d

DOUBLE INSULATED

The power tool is double insulated to provide a double
thickness of insulation between you and tool’s electrical
system. All exposed metal parts are isolated from
the internal metal motor components with protecting
insulation.

Replacement parts - When servicing use only identical
replacement parts.

Polarized plugs - This saw has a plug that looks ike

the one shown below:

To reduce the risk of electrical shock, this saw has a
polarized plug (one blade is wider than the other). This
plug will fit in a polarized outlet only one way. If the plug
does not fit fully in the outlet, reverse the plug. If it still
does not fit, contact a qualified electrician to install the
proper outlet. Do not change the plug in any way.

A WARNING

Double insulation does not take the place of normal

safety precautions when operating this tool.
To avoid electrocution:
1. Use only identical replacement parts when

servicing a too! with double insulation. Servicing
should be performed by a qualified technician.

2. Do not use power tools in wet or damp locations

or expose them to rain or snow.

MOTOR SAFETY PROTECTION

IMPORTANT:
To avoid motor damage, the motor should be blown out
or vacuumed frequently to keep sawdust from interfering
with the motor ventiiation.

1. CONNECT this saw to a 120V, 15 amp. circuit with a

15 amp. time delay fuse or circuit breaker. Using the

wrong size fuse can damage the motor.

2. If the motor won’t start, release the trigger switch

immediately. UNPLUG THE SAW. Check the saw
blade to make sure it turns freely. If the blade is free,
try to start the saw again. If the motor still does not
start, refer to the “TROUBLESHOOTING GUIDE”

3. If the tool suddenly stalls while cutting wood, release

the trigger switch, unplug the tool, and free the blade
from the wood. The saw may now be started and the
cut finished

4. FUSES may “blow” or circuit breakers may trip

frequently if:
a. MOTOR is overloaded - overloading can occur if

you feed too rapidly or make too many start/stops
in a short time.

b. LINE VOLTAGE is more than 10% above or

below the nameplate voltage rating. For heavy
loads, the voltage at motor terminals must equal
the voltage specified on the nameplate.

c. IMPROPER or dull saw blades are used.

5. Most motor troubles may be traced to loose or

incorrect connections, overload, low voltage or
inadequate power supply wiring. Always check the
connections, the load and supply circuit if the motor
doesn’t run well. Check minimum gauge for the
length of cord you are using on the chart below.

GUIDELINES FOR EXTENSION CORDS

Use a proper extension cord. Make sure your

extension cord is in good condition. When using an
extension cord, be sure to use one heavy enough to
carry the current your product will draw. An undersized
cord will cause a drop in line voltage, resulting in loss of
power and cause overheating. The table below shows
the correct size to use depending on cord length and
nameplate ampere rating. If in doubt, use the next
heavier gauge. The smaller the gauge number, the
heavier the cord.

Be sure your extension cord ts properly wired and
in good condition. Always replace a damaged extension

cord or have it repaired by a qualified person before
using it. Protect your extension cords from sharp
objects, excessive heat and damp or wet areas.

Use a separate electrical circuit for your tools.

This circuit must not be less than # 12 wire and should
be protected with a 15 Amp time delay fuse. Before
connecting the tool to the power line, make sure the
switch is in the OFF position and the electric current is

rated the same as the current stamped on the motor
nameplate, running at a lower voltage will damage the
motor.

MINIMUM GAUGE FOR EXTENSION CORDS (AWG)

I (When

usng

120 volts only) |

I Ampere Rating

I

Total length

of Cord |

More Than

Not More Than25ft.

50ft.

100ft.

150ft.

0

6

18ft.

16ft.

16ft.

14ft.

6

10

18tl. 16ft.

14ft.

12

ft.

10

1?

16ft.

16ft.

14ft.

120

-.

14fi-:V:1.2ftV:i

CAUTION: In all cases make certain the receptacle
in question is properly grounded. If you are not sure
have a certified electrician, check the receptacle.