Chicago Electric Heavy Duty Oxy - Acetylene Welding Outfit 92496 User Manual

Page 10

Advertising
background image

SKU 92496

PAGE 10

your gas supplier immediately. (See figure f.)

7.

Connect the Cutting Attachment (parts C1-C27) to the Torch Handle (parts B1-B10).
Always check the Connector (C23) and Coupling Nut (C22) for damage or oil. If
either are found, discontinue use and contact your gas supplier.

TORcH HAnDlE

(PARTS B1-B10)

RED (Ac) WElDInG HOSE (D1B)

GREEn (Ox) WElDInG HOSE

(D1A)

fIGURE f

Make sure the two O-Rings (c24, c25) are not damaged or miss-
ing, otherwise gases will mix inside the Torch Handle (parts B1-

B10) and result in flashback or backfires. (See figures G, and H.)

cUTTInG ATTAcHMEnT (PARTS c1-c27)

O-RInG

(c25)

O-RInG

(c24)

cOnnEcTOR (c23)

cOUPlInG nUT (c22)

fIGURE G

cUTTInG ATTAcHMEnT (PARTS c1-c27)

TORcH HAnDlE (PARTS B1-
B10)

fIGURE H

GREEn (OxYGEn)

WElDInG HOSE

(D1A)

8.

Check connections for leaks. Adjust the Acetylene Regulator (parts 1-19) and
Oxygen Regulator (parts A1-A20E) to their normal operating pressure. Use an
approved leak detection solution to check for

leaks at the Welding Hoses (D1A,

and D1B) and cylinder valve connections. If leaks are found, tighten the nuts more

WARnInG!

RED (AcETYlEnE)

WElDInG HOSE

(D1B)