SKU 92496

PAGE 9

5.

IMPORTAnT! The Pressure Adjusting Screw (18) on the Acetylene Regulator and
the Pressure Adjusting Screw (A18) on the Oxygen Regulator should be opened
slightly by turning counterclockwise to relieve pressure on the Regulator diaphragms
before opening the cylinder valves. If this is not done, pressure from the cylinders
may damage the diaphragms and render the Regulators inoperable.

RED

AcETYlEnE

REGUlATOR

(parts 1-19)

GREEn

OxYGEn

REGUlATOR

(PARTS A1-A20E)

PRESSURE

ADJUSTInG

ScREW

(18)

PRESSURE

ADJUSTInG

ScREW

(A18)

cYlInDER

VAlVE

cYlInDER

VAlVE

AcETYlEnE

cYlInDER

(nOT InclUDED)

OxYGEn

cYlInDER

(nOT InclUDED)

RED

WElDInG

HOSE

(D1A)

GREEn

WElDInG

HOSE

(D1B)

6.

Connect the

GREEn and RED Welding Hoses (D1A, or D1B) to the proper con-

nections on the Torch Handle (parts B1-B10).

WARnInG! If any traces of oil or grease are found, do not use. contact

TORcH

HAnDlE

(PARTS B1-B10)

cUTTInG

ATTAcHMEnT

(PARTS c1-c27)

WElDInG nOZZlE (D4),

OR cUTTInG nOZZlE (D6)

fIGURE E

REV 08g