f "----- " ............

SYMPTOM

CAUSE

SOLUTION

Engine won’t

start

1.

Engine throttle is in

"OFF"

Position.

2. Choke lever has not been placed to

choke.

3. Pressure buildup after initial use.

1

. Slide throttle to "Rabbit" position.

2. Slide choke lever to choke position.

j

3. Depress trigger gun.

Won’t Draw

1. Nozzle not in chemical draw position.

1. Place nozzle to low pressure.

Ghemica!

2. Chemical screen is obstructed.

2. Check chemical screen; clean if obstructed.

3. Chemical screen not

working.

3.

Make

sure

chemical screen is submerged in

chemical/water.

4. Chemical injector orifice obstructed

or stuck.

4. Check and clean.

5. Chemical injector closed.

5. Open chemical injector by turning adjustment

knob.

Pump running

1

, Water supply restricted.

1

. Check water supply and filter screen for.

normally but

blockage. Check hoses for blockage, kinks,

pressure does

leaks, etc.

not achieve

2. Nozzle is in low PS! position.

2. Twist nozzle at end of wand clockwise the high

rated values

pressure position.

3. Nozzle incorrect or worn.

3. Check and replace.

4. Pump sucking air.

4. Check that hoses and fittings are air-tight.

5. Nozzle blocked.

5. Clean nozzle.

Fluctuating

1. Pump sucking air.

1. Check that hoses and fittings are air tight. Purge air j

Pressure

from garden hose.

2. Garden hose inlet strainer dogged.

2. Clean. Check filter frequently.

3. Worn Seals or Packing.

3, Check and replace.

4. Inadequate water supply.

4. Check hose for kinks.

5. Fouled or dirty inlet or discharge

5. Check flow available to pump. Check for

valves.

excessive heat, 145® F or above.

6. Leaky discharge hose.

6. Glean inlet and discharge valve assemblies.

Replace if damaged.

Pressure drops

1

. Nozzle clogged, partially obstructed.

1. Use nozzle cleaning kit to clear obstruction. (See

after period of

Nozzle Maintenance under Service Adjustment.)

normal use

2. Nozzle worn.

2, Clean or replace.

3. Pump Valves worn, dirty or stuck.

3. Check and replace.

4. Worn pump piston packing.

4. Check and replace.

Pump noisy

1

. Water

too hot.

1. Reduce temperature below 63® C or 145® F,

2. Pump sucking air.

2. Check that hoses and fittings are air tight.

3. Valves dirty or worn.

3. Check, clean or replace.

4. Worn bearings.

4. Check and replace If necessary.

Presence of

1. High humidity.

1. Change Oil.

water in oil (oi!
milky).

2. Piston packing and oil seal worn.

2. Check and replace

oil

seals.

Water dripping

1.

Thermal relief functioning normal.

1

. Protecting pump, if not using pressure washer

for

from pump

2. Fittings Loose,

a long period

of

time, shutoff engine.

3. O-rtngs of piston guide or retainer

2. Tighten.

worn.

3. Check and replace.

4. Piston packing worn.

4. Check and replace.

Ois Dripping

1, Oil seal

worn

1. Check and replace

2. Loose drain plug or worn drain plug

2, Tighten drain plug or replace O-ring. Do not over torque.

o-ring.