Frame relay configuration, Internal t1 csu/dsu (wan 0) link configuration, Required for dedicated/leased line operation – Compatible Systems 1250I User Manual

Page 31: Suggested for dedicated/leased line operation, Rs-232 (wan 1) link configuration

Advertising
background image

Chapter 6 - Basic Configuration Guide

25

monitor link usage to determine whether the link is being activated only
when it is needed. Additional router configuration will be required for
many networks in order to achieve optimal link usage.

Set update method

CV: Use the IPX Routing: WAN Dialog Box.

TB: Use configure and set the Updates keyword in the IPX WAN 0

(and/or WAN 1) section.

Frame Relay Configuration

This section covers the settings required for Frame Relay operation of
the MicroRouter 1250i WAN interfaces. In general, the parameters
listed here should be set for each WAN interface on which you plan to
use Frame Relay. Note that the T1 (WAN 0) interface can be running
Frame Relay, SMDS or PPP while the RS-232 interface (WAN 1) is
running PPP or Frame Relay.

Internal T1 CSU/DSU (WAN 0) Link Configuration

Required for Dedicated/Leased Line Operation

This is the only mode of operation supported via the built-in T1
CSU/DSU.

Set Frame Relay connection

CV: Use the Link Configuration: WAN 0 Dialog Box.

TB: Use configure to set the Mode keyword in the Link Config

WAN 0 section.

Suggested for Dedicated/Leased Line Operation

Dedicated line operation generally does not require additional parame-
ters for operation.

RS-232 (WAN 1) Link Configuration

Frame Relay is presently supported in the MicroRouter 1250i only via
dedicated line operation.

Set Dedicated connection

Set Frame Relay connection

CV: Use the Link Configuration: WAN 1 Dialog Box.

TB: Use configure to set the Mode and ConnectMode keywords in

the Link Config WAN 1 section.

Advertising