Salter Brecknell S122 User Manual
Page 43
Advertising

43
S122
User /
Service Instructions
5 Configuration Mode
5.4 F1 - specification settings
Press
and
to
enter the required capacity:
Full capacity + 9d
max lb w
i
ght=(max kg
wghtx2.24)
60kgx20g 006018
150kgx50g 015045
300kgx100g 003009
130lbx0.05lb 013045
330lbx0.10lb 003309
660lbx0.20lb 066010
Press
and
to
enter the weight settings:
digit 1 = divisions (1, 2, or 5)
digit 2 = decimal places
(1, 2, or 3)
digits 3 - 6 = 0
ZERO
C00000
kg
lb
ENTER
013045
kg
130lb capacity
lb
ZERO
d00000
kg
lb
ENTER
530000
kg
lb
Divisions=0.05lb
ZERO
Advertising
See also other documents in the category Salter Brecknell Scales:
- PB500 (4 pages)
- PB250 (12 pages)
- MB2610 (4 pages)
- MBS Series (14 pages)
- 302BP (6 pages)
- 304BP (26 pages)
- 308BP (27 pages)
- APD-100 (36 pages)
- CB100 (8 pages)
- ESA Series (14 pages)
- LPS30 (18 pages)
- PC150 (13 pages)
- SP60 (9 pages)
- 3700LP (20 pages)
- C3235 (16 pages)
- C3255 (18 pages)
- C3225 (40 pages)
- B140 (32 pages)
- B120 (19 pages)
- B130 (22 pages)
- 610 (23 pages)
- 630 (24 pages)
- 650 (43 pages)
- B220 (24 pages)
- B225 (44 pages)
- CS Series Crane (12 pages)
- 3800LP Series Calibrated with SBI-505 LED Indicator (22 pages)
- 405 (12 pages)
- LPS150 (30 pages)
- GP100 (13 pages)
- S100 (17 pages)
- PS150 (15 pages)
- 6702 (28 pages)
- 6712 (24 pages)
- PS250 (28 pages)
- PS500 (19 pages)
- PS1000 (38 pages)
- PS3000HD (18 pages)
- SBI140 (35 pages)
- SBI100 (34 pages)
- SBI-521 (82 pages)
- 200 Series (47 pages)
- 200SL (2 pages)
- 400ES (30 pages)