1 safety notices, 2 fault indications, 3 causes and rectification of faults – CASO Germany MCG 20 chef User Manual

Page 69: Attention

Advertising
background image

caso MCG20 Chef

69

14.1 Safety notices

Attention

► Only qualified electricians, who have been trained by the manufacturer, may carry out

any repairs on electrical equipment.

► Improperly performed repairs can cause considerable dangers for the user and

damages to the device.

14.2 Fault indications

In the event of a fault, an error code will appear in the display; it describes the

cause of the fault.

Error code

Description

E01

Excessive temperature within cooking chamber

The overheating cut-out terminated the current program at a cooking
chamber temperature of 250°C.

Press the Stop button to acknowledge this fault.

The device can be re-activated after the cool down phase.

E03

Sensor fault

The device has detected an error on a sensor and has terminated the
current programme.

Press the Stop button to acknowledge this fault.

Please note

► If error messages continue to appear after an extended waiting period and restarting the

device, then the device will need to be sent to Customer Service to be inspected.

14.3 Causes and rectification of faults

The following table assists in localizing and rectifying minor faults.

Error

Possible cause

Action

The selected program
will not start.

Device door is not closed

► Close device door

Power plug is not plugged in

► Plug in mains plug!

Fuse is not activated

► Activate fuse

The turntable turns
jerkily.

Dirt between the turntable and
the base of cooking camber

► Remove dirt

Dirt on rolling ring

Cooking vessel too large

► Use different cooking

vessel

Advertising