Torque/force transducers, Multitest manual loader specifications – CDI Torque MULTITEST Government User Manual

Page 29

Advertising
background image

2-13

Functional Description and Specificatons

Torque/Force Transducers

Accuracy

±0.2% of reading @ 25°C, within specified range, when used as

prescribed with the 2000-610-02 Loader.

Range and Resolution

Refer to transducer-indicator range and display resolution tables

in Functional Description of this chapter.

Temperature

Operating Temperature

10 to 32°C (50 to 90°F)
Storage

-20 to 50°C (-2 to 122°F)
Humidity

Up to 90% non-condensing
Temperature Drift

+0.02%/°C (+.011%/°F)

MULTITEST Manual Loader Specifications

Input Torque (Hand Crank)

8 ft lb maximum

Output Torque

2000 ft lb ±20 degrees rotation maximum

Power Requirements (Safety solenoids)

115/230VAC ±10%, @ 50-60 Hz

Physical Dimensions

Width
45"
Height
50"
Depth
24"

Weight (including 2000-100-02 roll cab)

1500 lbs

Optional Calibration Fixturing (Load bars and weights)

±0.05% accuracy

Advertising