CellarPro MINI-SPLIT 3000S REFRIGERATION SYSTEM, 1713 User Manual

Page 33

Advertising
background image

33

V10.14

humidity inside the cellar, the Fon setting can be changed as described in the
“Advanced Operation” section later in this chapter.

Switch Instructions

(1) Control Panel: Maintains desired cellar environment. Factory settings are
optimized for peak performance. Controller is described in detail in the following
section.

(2) Fan Speed Selector Switch (Low/Med/High): The cooling unit fans operate on 3
speed settings: Low, Medium, and High. For optimum sound and energy efficiency,
select the lowest fan speed that will maintain the desired cellar temperature. High
speed is recommended for initial cellar pull down,

extreme

temperature conditions

and ducted installations.

(3) Bottle Probe Jack (Bottle Probe): Plug in the remote bottle probe (sold
separately) to control the cellar by liquid temperature rather than air temperature
inside the cellar. Disconnecting the probe will automatically return the control to air
temperature. When using a bottle probe, the Temperature Differential will need to
be adjusted to 1 as shown in the

“Advanced Operation” instructions below.

Advertising